The rate of drying of test materials is measured using 3.5 inch
diameter circle test specimens. Dry weight of the test specimens
is determined. Then one cubic centimeter (one gram) of distilled
water is evenly distributed over the fabric surface. The specimens
are weighed every 15 minutes until they return to their approximate
original dry weight. The average drying time in minutes is calculated
for each test material.
|